FCRDIV=000, LOCS0=0, ATMF=0, ATMS=0, ATME=0, FLTPRSRV=0
MCG Status and Control Register
| LOCS0 | OSC0 Loss of Clock Status 0 (0): Loss of OSC0 has not occurred. 1 (1): Loss of OSC0 has occurred. |
| FCRDIV | Fast Clock Internal Reference Divider 0 (000): Divide Factor is 1 1 (001): Divide Factor is 2. 2 (010): Divide Factor is 4. 3 (011): Divide Factor is 8. 4 (100): Divide Factor is 16 5 (101): Divide Factor is 32 6 (110): Divide Factor is 64 7 (111): Divide Factor is 128. |
| FLTPRSRV | FLL Filter Preserve Enable 0 (0): FLL filter and FLL frequency will reset on changes to currect clock mode. 1 (1): Fll filter and FLL frequency retain their previous values during new clock mode change. |
| ATMF | Automatic Trim machine Fail Flag 0 (0): Automatic Trim Machine completed normally. 1 (1): Automatic Trim Machine failed. |
| ATMS | Automatic Trim Machine Select 0 (0): 32 kHz Internal Reference Clock selected. 1 (1): 4 MHz Internal Reference Clock selected. |
| ATME | Automatic Trim Machine Enable 0 (0): Auto Trim Machine disabled. 1 (1): Auto Trim Machine enabled. |